beautypg.com

Ransburg, Vector r series cascade applicators - waterborne, Environmental/physical electrical mechanical – Ransburg Vector R Series Cascade 79523 R90 Waterborne User Manual

Page 63: Electrical, Physical, Pneumatic

background image

Vector R Series Cascade Applicators - Waterborne

Ransburg

59

Fluid Flow

Capacity:

1000 cc/minute**

Operating Pressure (Air Spray)

Fluid:

(0-6.9 bar) 0-100 psi

Air:

(0-6.9 bar) 0-100 psi

Ambient Temp.:

40°C to 12.8°C

Consumption:

510 slpm (18.0 SCFM) @

3.4 bar (50 psig) inlet

Sound Level:

92dB (A) @ 50 psig inlet,

1m from applicator

** This reflects the maximum fluid volume the appli-

cator can deliver. The maximum spray volume that

can be effectively atomized depends on fluid rheology,

spray technology, and finish quality required.

Gun Length:

27cm (10.7 inches)

Weight:

735 grams (25.9 oz.)

Hose & Cable

Lengths (Std): 10m, 15m, 20m, 25m,

and 30m

Atomizer Nozzle

Assembly (Std):

79374-65, 79377-45

Operating Voltage: 85 kV DC (-) maximum

Current Output:

100 microamperes maximum

Part Sprayability:

Determine sprayability of

part to be coated using

76652, Test Equipment

(See current "Paint, HV & SCI Test Equipment"

service manual.)

79523 R90 CASCADE

WATERBORNE

SPECIFICATIONS

Environmental/Physical

Electrical

Mechanical

79513-1XX 9050 POWER

SUPPLY ELECTRICAL

SPECIFICATIONS

Input Voltage:

100-240 VAC

Current:

1 A maximum RMS

Frequency:

50/60 Hz

Wattage:

40 watts (max.)

Output Voltage:

20-85 kV DC (79513-12X)

Current:

100 microamps (max.)

(79513-12X)

Electrical

Height:

14.0cm (5.5-inches)

Width:

21.6cm (8.5-inches)

Depth:

19.1cm (7.5-inches)

Weight:

3.4 kg (7.5 lbs.)

Physical

Supply Air:

6.9 bar (100 psig) maximum

Pneumatic

110/120 VAC

220/240 VAC

79513-121
79513-122

-85 kV DC
-85 kV DC

Voltage

Designation

Maximum

Output

9050

Part #

CONTROL UNIT INPUTS / OUTPUTS

79523-XXXXX

79513-12X

For Use With Applicator

Combinations

9050

Part #

CONTROL UNIT / APPLICATOR

COMBINATIONS

AH-06-01.13