Vector R Series Cascade Applicators - Installation
Ransburg
18
79500 R90 SOLVENTBORNE
79501 R70 SOLVENTBORNE
INSTALLATION
The control unit
MUST be located out-
side of the spray area.
The User
MUST read and be familiar
with the "Safety" section of thismanual.
This manual
MUST be read and thor-
oughly understood by
ALL personnel who
operate, clean, or maintain this equipment!
Special care should be taken to ensure that
the warnings and requirements for operating
and servicing safety are followed. The user
should be awre of and adhere to
ALL local
building and fire codes and ordinances as
well as NFPA, OSHA, and all related coun-
try safety codes prior to installing, operating,
and/or servicing this eqiupment.
The fluid lines and fluid sources
MUST
be isolated from ground for waterbase ap-
plications.
Personnel
MUST be GROUNDED to
prevent a shock or spark during electrostatic
operation.
Install and route the hoses and cable so
they are
NOT exposed to temperatures in
excess of 120°
F and so that all hose and
cable bends are
NO LESS than a 6 inch
(15cm) radius. Failure to comply with these
parameters cold cause equipment malfunc-
tion that might create
HAZARDOUS CON-
DITIONS!
Install only one spray applicator per iso-
lated waterborne fluid supply system.
W A R N I N G
!
NEVER wrap the applicator, associated
valves and tubing, and supporting hardware
in plastic to keep it clean. A surface charge
may build up on the plastic surface and dis-
charge to the nearest grounded object. Effi-
ciency of the applicator will also be reduced
and damage or failure of the applicator
components may occur.
WRAPPING THE
APPLICATOR IN PLASTIC WILL VOID
WARRANTY. Only approved applicator
covers should be used.
W A R N I N G
!
TYPICAL
SOLVENTBORNE
INSTALLATION
(See "Figure 3 - Typical Solventborne
Installation Features")
Location of Control Unit
Install the low voltage control unit in an area
out-
side the hazardous location in accordance with
federal, state, and local codes. The area should
protect the control unit from the possibility of en-
vironmental intrusion (such as dust or moisture),
have ambient temperatures that do not exceed
120°F, and be as close to the applicator as pos-
sible to minimize the length of low voltage cable.
INSTALLATION
AH-06-01.13