Ransburg, Vector r series cascade applicators - operation, Front panel lockout – Ransburg Vector R Series Cascade 79523 R90 Waterborne User Manual
Page 32: Applicator switch lockout, Overload activation
![background image](/manuals/348081/32/background.png)
Vector R Series Cascade Applicators - Operation
Ransburg
28
Front Panel Lockout
This feature locks out any changes to the kV setting
from the front panel of the control unit.
1. Set the kV to the desired value using the front
panel buttons. This must be set prior to installing
the jumper.
2. Turn AC power off and access the interior of
the control unit.
3. Place the jumper across the two (2) pins at
location 16 on the main PC board (see Figure 9).
4. Close the control unit and turn AC power back
on. Pressing the front panel +, -, or setpoint but-
tons will now have no effect on the kV setting.
Figure 9: Jumper Location - Front
Panel Lockout
Applicator Switch Lockout
The applicator switch may be de-activated for
applications that require the operator to not be
able to change settings or turn the applicator off
at the applicator.
1. Turn AC power off and access the interior of
the control unit.
Figure 10: Jumper Location - Applicator
Switch Lockout
2. Place the jumper across the two (2) pins at
location 15 on the main PC board (see Figure 10).
3. Close the control unit and turn AC power back
on. It will now be no longer possible to change
setpoints or turn kV off at the applicator.
Overload Activation
The overload circuit may be activated for appli-
cations that require notification of high applicator
output currents. The overload value is set in the
software and is maximum microamp rating minus
10 microamps.
1. Turn AC power off and access the interior of
the control unit.
2. Place the jumper across the two (2) pins at
location 17 on the main PC board (see Figure 11).
3. Close the control unit and turn the AC power
back on. An overload fault will now occur if the
microamp display comes within 10 microamps of
the maximum current.
AH-06-01.13