Ransburg, Vector r series cascade applicators - atex/fm, Fm configuration – Ransburg Vector R Series Cascade 79523 R90 Waterborne User Manual
Page 10

VECTOR R SERIES 79500, 79501,
AND 79523 ATEX PRODUCT
MARKING DEFINITIONS
Ex Certificate Number: Sira 06ATEX5282X
Sira = Notified Body performing EC-type
examination
06 = Year of certification
ATEX = Reference to ATEX Directive
5 = Protection Concept Code (code 5 is titled
Encapsulation)
282 = Document serial number
X = Special conditions for safe use apply
Special conditions for safe use: The Vector 79500,
79501, and 79523 R Series Cascade Applicators
shall only be used with associated 80131-21X
Control Unit.
Product Marking
II 2 G
Ex = Specific marking of explosive protection
II = Equipment Group hazardous area character-
istics
2 = Equipment Category
G = Type of explosive atmosphere (gases, vapors,
or mists)
EEx 0.24mJ = The Vector R Series 79500, 79501,
and 79523 Cascade Applicators are suitable for
use in manual spraying installations complying
with EN 50 050 as they are a Type A class with a
discharge energy limit of 0.24mJ.
Vector R Series Cascade Applicators - Atex/FM
Ransburg
Label 79516-70
Label 79515
Label 79516-91
Label 79516-90
Label 80108
FM Configuration
These applicators are FM approved when config-
ured to drawings 79946, 79947, 79951, shown on
pages 7 thru 12.
6
E N 5 0 0 5 0 COM P L I A N T
Label 80082
Label 80081
AH-06-01.13