Ransburg, Troubleshooting guide, Vector r series cascade applicators - maintenance – Ransburg Vector R Series Cascade 79523 R90 Waterborne User Manual
Page 54

Vector R Series Cascade Applicators - Maintenance
Ransburg
50
Blown fuse
Is the power turned on?
Is the atomizing air turned on?
Is the applicator triggered?
Is the applicator switch on?
Is the paint too conductive?
Faulty flow switch
Replace fuse.
Check power supply.
Check air regulator.
Check applicator trigger.
Check applictor switch.
Check conductivity of paint.
Replace flow switch.
TROUBLESHOOTING GUIDE
(Cont.)
General Problem
Possible Cause
Solution
ELECTRICAL (Continued)
Improper or No High
Voltage (Cont.)
Isolation System
Grounded Out
Failed fluid hose
Insolation stand or charged
equipment too close to ground
Replace fluid hose.
Provide adequate ground distance.