beautypg.com

Wiring guidelines – AMX G3 User Manual

Page 22

background image

14

Installing Touch Panels

Color Active-Matrix LCD Touch Panels

2.

Insert each wire into the appropriate opening on the connector according to
the wiring diagrams and connector types described in this section.

3.

Turn the flat-blade screws clockwise to secure the wire in the connector.

Wiring guidelines

Touch Panels require regulated 12 VDC power to operate properly. The AXCESS
Central Controller supplies power via the AXlink cable. The maximum wiring
distance between the control system and Touch Panel is determined by power
consumption, supplied voltage, and the wire gauge used for the cable. Figure 13
lists wire sizes and the maximum lengths allowable between the Touch Panel and
control system. The maximum wiring lengths for using AXlink power are based on
a minimum of 13.5 volts available at the control system’s power supply.

Wiring guidelines for Touch Panel (800 mA)

Wire size

Maximum wiring length

18 AWG

146.71 feet (44.71 m)

20 AWG

92.8 feet (28.29 m)

22 AWG

57.9 feet (17.65 m)

24 AWG

34.5 feet (10.52 m)

If you install the Touch Panel farther away from the control system than
recommended in Figure 13, connect an external 12 VDC power supply as shown in
the wiring diagrams in this section.

Caution

Do not over-torque the

screw. Doing so can bend

the seating pin and damage

the connector.

Figure 13

Wiring guidelines 800 mA.

See the Specifications

section for power information.

Note

For information on the maxi-

mum power consumption of

each device, see the

Specifications section.