Programming Numeric Data Values:


The presets, prescaler, and output time values may be accessible when the unit is in the
normal operating mode (not programming mode), providing that the Program Disable input is

not activated. Pressing the

key will sequence the secondary display through the available

presets, prescaler, and output time values.

To change a numeric data value it must be visible on the secondary display. Pressing the

or

key will allow changing of the value. The two methods for changing numeric data values

are "digit entry" and "auto scrolling".

Digit Entry:


If the data entry method has been set to "digit entry", the least significant digit will blink.

Pressing the

key multiple times will select other digits. Pressing the

will increment the

selected digit. The data value will be entered when the

key is pushed, or the old value will

be retained if no key activity is detected for 10 seconds.

Short-Cut - Decrementing Value

To decrement a digit value, press and hold the

key and then press the

key. This will

decrement the selected digit to zero if held.