17. Insert the Catalyst Injector and injector seal into the aperture in the Distribution Ring. The
spring goes into the gun block.
18. Place Mix Chamber and Catalyst Injector onto the front of the Pro Gun, secure it with the
2 screws.
19. Flush the assembled mix chamber with solvent.
20. Apply a little red grease (6706-2-1) to the threads of the mix chamber.
21. Install the RTM-LT-CK onto the mix chamber.
DAILY SHUT-DOWN:
1.
Disconnect the gun from the injection port.
2.
Flush the gun with solvent.
3.
Remove RTM-LT-CK assembly from the mix chamber.
4.
Turn off the main inlet air ball valve at the manifold.
5.
Turn off power to the Control Box.
6.
Release the solvent flush tank pressure, by lifting pressure relief valve.
7.
Release Catalyst pressure by opening the recirculation valve on the catalyst manifold.
8.
Remove the Mix Housing and clean it.
9.
Wipe the gun block face with a clean rag.
10. Hang the gun with the gun block exit holes facing down.
Emergency Stop:
If the emergency stop button is pushed during operation the gun and pump will stop. To
restart pull out the emergency stop button and push the gun
“ON” button.
It may take a split second for the pump to stop traveling and a count might be registered on
the counter. So beware you will want to monitor the amount of material injected into the mold
and correct for this situation. This condition could also occur if the gun is turned off during the