beautypg.com

Model e1616 - wiring, Wiring model e1616, Lectrocount lcr – Liquid Controls XL LED Display E1615_E1616_E1617_E1618 User Manual

Page 9: Lectrocount, J1 jumper - lectrocount xl led remote display, Shielded cable, 24 vdc power

background image

moDEL E1616 - wIRInG

wiring model E1616

Model E1616 of the LectroCount XL LED Remote Display is designed for use with a LectroCount LCR (CPU board

81547-2) or a LC3 CPU board (Terminal Board 81924).

to wire the LectroCount XL LED Remote Display model E1616 to a 81547-2 or LC3 CPu board:

1. Open the LectroCount register. Refer to the specific LectroCount register’s manual for specific instructions regarding opening,

closing, and sealing the electronic register.

2. Attach a cable gland and/or conduit connector to a port on the LectroCount electronic register.
3. Route the shielded cable through the cable gland and into the

LectroCount register housing.

4. Connect the four wires of the display’s shielded cable to the four

designated terminals on the LectroCount CPU board.

4a.

LectroCount LCR

On the J12 terminal block (81547-2) connect:

• XL LED terminal 53 (red wire) to LCR terminal 45

• XL LED terminal 54 (white wire) to LCR terminal 39

• XL LED terminal 55 (green wire) to LCR terminal 40

• XL LED terminal 56 (black wire) to LCR terminal 41

4b.

LectroCount

3

On the J1 terminal block (81924) connect:

• XL LED terminal 53 (red wire) to LC3 terminal 1

• XL LED terminal 54 (white wire) to LC3 terminal 5

• XL LED terminal 55 (green wire) to LC3 terminal 6

• XL LED terminal 56 (black wire) to LC3 terminal 2

5. Tighten the cable gland and close the LectroCount register.

81547-2

CPU Board

Remote Display

PCB Board

GND/

Blac

k (41)

OUT 4/

Green

(40)

+V

o/

Re

d (45)

GND/

Blac

k (56)

A/

Green

(55)

B/

White

(54)

PWR/

Re

d (53)

Jumper

OUT 5/

White

(39)

Shieled cable

ground wire

grounded to

remote display

PCB board

A jumper is required between terminal 52 and terminal 53 on the display’s J1 terminal block. Display

units from the factory will include the jumper. When rewiring, ensure that this jumper is in place.

J1 Jumper - LectroCount XL LED Remote Display

The LectroCount XL LED Remote Display

is supplied with a 30 foot 4-wire shielded

cable with 22 gauge wire. If alternate

cabling is required, Liquid Controls

recommends a similar 4-wire shielded

cable with 22 gauge wire or larger and a

maximum cable length of 30 feet.

Shielded Cable

If the power to the LectroCount LCR exceeds

24 VDC, then the remote display should be

powered from Pin 32 on J8, 5 VDC.

24 VDC Power

LC

3

CPU Board

Remote Display

PCB Board

GND/Black (2)

OUT 4/Green (5)

+Vo/Red (1)

GND/

Blac

k (56)

A/

Green

(55)

B/

White

(54)

PWR/

Re

d (53)

Jumper

OUT 5/White (6)

Shieled cable

ground wire

grounded to

remote display

PCB board

Display and LectroCount LCR Wiring

Display and LectroCount

3

Wiring

9