wIRInG - moDEL E1615

wiring model E1615

Model E1615 of the LectroCount XL LED Remote Display is designed for use with a LectroCount LCR-II or LCR 600.

LectroCount LCR-II or LCR 600 electronic registers contain a 840404, 84040, or 81920 CPU board.

to wire the LectroCount XL LED Remote Display model E1615 to a 840404, 84040, or 81920 CPu board:

1. Open the LectroCount register. Refer to the specific LectroCount register’s manual for specific instructions regarding opening,

closing, and sealing the electronic register.

2. Attach a cable gland to a port on the LectroCount electronic register.
3. Route the shielded cable through the cable gland and into the

LectroCount register housing.

4. Connect the four wires of the display’s shielded cable to the four

designated terminals on the J12 terminal block on the LectroCount

CPU board.

• XL LED terminal 53 (red wire) to LCR-II/600 terminal 45

• XL LED terminal 54 (white wire) to LCR-II/600 terminal 39

• XL LED terminal 55 (green wire) to LCR-II/600 terminal 40

• XL LED terminal 56 (black wire) to LCR-II/600 terminal 41

5. Tighten the cable gland and close the LectroCount register.

840404, 84040,

or 81920 CPU Board

Remote Display

PCB Board

Shieled cable

ground wire

grounded to

remote display

PCB board

GND/

Blac

k (41)

OUT 4/

Green

(40)

+V

o/

Re

d (45)

GND/

Blac

k (56)

A/

Green

(55)

B/

White

(54)

PWR/

Re

d (53)

Jumper

OUT 5/

White

(39)

If the power to the LectroCount

LCR-II or LCR 600 exceeds 24

VDC, then the remote display

should be powered from Pin 32 on

J8, 5 VDC.

24 VDC Power

A jumper is required between terminal 52 and terminal 53 on the display’s J1 terminal block. Display

units from the factory will include the jumper. When rewiring, ensure that this jumper is in place.

J1 Jumper - LectroCount XL LED Remote Display

The LectroCount XL LED Remote Display

is supplied with a 30 foot 4-wire shielded

cable with 22 gauge wire. If alternate

cabling is required, Liquid Controls

recommends a similar 4-wire shielded

cable with 22 gauge wire or larger and a

maximum cable length of 30 feet.

Shielded Cable