decIMal Place JuMPer settInG
Decimal Place Jumper Setting -
moDEL E1616
The decimal place setting of model E1616 LectroCount XL LED Remote Displays is determined by the position of
jumpers on the J3 and J4 terminals on the PCB. The terminals are located on the bottom of the PCB on the left side.
to set the decimal place of model E1616 LectroCount XL LED Remote Displays:
1. Remove the rear panel of the display.
2. Slide the J3 and J4 jumpers over the terminal pins in the desired position.
see table below
Decimal Jumper Settings ─ Model
E1616
Units
Whole
tenths
Hundredths
JUmper
J3
J4
J3
J4
J3
J4
position
OFF
OFF
ON
OFF
OFF
ON
The decimal place displayed on Model
E1615 coincides with the LectroCount
LCR-II/LCR 600 decimal place setting and
does not require positioning of the jumpers.
For Model E1616 Only
TENTHS
Factory Default Setting
Do not remove and discard jumpers. The absence of a jumper
does not qualify as the OFF position. If Whole Units is desired,
J3 and J4 must both have a jumper in the OFF position.
Jumpers Must Be on Terminal Pins
If J3 and J4 are both in the ON position, two
decimal points will appear on the display. This
is not a valid jumper configuration.
3. Replace the rear panel of the display. page 18 Torque Specifications
LectroCount XL LED Remote Displays are assembled and shipped ready for final cable termination.
If the display’s pre-installed shielded cable is removed during installation, be sure to secure the cable
and tighten the cover so the vapor seal is maintained. See page 18 for proper torque specifications.
Secure Cable and Tighten Cover Upon Reassembly