decIMal Place JuMPer settInG

Decimal Place Jumper Setting -

moDEL E1616

The decimal place setting of model E1616 LectroCount XL LED Remote Displays is determined by the position of

jumpers on the J3 and J4 terminals on the PCB. The terminals are located on the bottom of the PCB on the left side.

to set the decimal place of model E1616 LectroCount XL LED Remote Displays:

1. Remove the rear panel of the display.
2. Slide the J3 and J4 jumpers over the terminal pins in the desired position.

see table below

Decimal Jumper Settings ─ Model

E1616

Units

Whole

tenths

Hundredths

JUmper

J3

J4

J3

J4

J3

J4

position

OFF

OFF

ON

OFF

OFF

ON

The decimal place displayed on Model

E1615 coincides with the LectroCount

LCR-II/LCR 600 decimal place setting and

does not require positioning of the jumpers.

For Model E1616 Only

TENTHS

Factory Default Setting

Do not remove and discard jumpers. The absence of a jumper

does not qualify as the OFF position. If Whole Units is desired,

J3 and J4 must both have a jumper in the OFF position.

Jumpers Must Be on Terminal Pins

If J3 and J4 are both in the ON position, two

decimal points will appear on the display. This

is not a valid jumper configuration.

3. Replace the rear panel of the display. page 18 Torque Specifications

LectroCount XL LED Remote Displays are assembled and shipped ready for final cable termination.

If the display’s pre-installed shielded cable is removed during installation, be sure to secure the cable

and tighten the cover so the vapor seal is maintained. See page 18 for proper torque specifications.

Secure Cable and Tighten Cover Upon Reassembly