wiring model E1618 (Single Channel Pulsers)

Model E1618 of the LectroCount XL LED Remote Display is designed to receive a calibrated single channel pulse

output. A common application of Model E1618 is with a 100 pulses per revolution solid state single channel pulser (PN

07525) mounted onto a mechanical register using mounting kit (PN 42695). The E1618 is also compatible with any

single channel pulser that meets the required specifications listed below.
Since single channel pulsers do not have an output signal to reset the LED Remote Display, a Reset Switch Kit (PN

82592) is required for this application. The Reset Switch Kit resets the XL LED Remote Display to zero between

deliveries. To complete the installation, the installer must provide a 5 to 28 VDC external power source and a junction

box.

to wire the LectroCount XL LED Remote Display model E1618 to

a single channel pulser:

1. Install Reset Switch Kit. page 16
2. Set the junction box.
3. Route the display’s shielded cable, the pulser wires, and the wires from the

external power source into the junction box. Use the appropriate connectors.

4. Connect the display’s shielded cable wires to the following pulser and

external power source wires:

• XL LED terminal 53 (red wire) to Pulser power to External Power Source voltage (+Vo)

• XL LED terminal 54 (white wire) to Pulser signal

• XL LED terminal 56 (black wire) to Pulser ground to External Power Source ground

5. Tighten connectors and close the boxes.

wIRInG - moDEL E1618

Junction Box

2A Fuse

5 to 28 VDC

DC GND

Remote Display

PCB Board

GND (56)

GND

B (54)

PWR

(53)

VDC

SIGNAL

Jumper

EXTERNAL

POWER

SOURCE

Single Channel Pulser

GND

VDC

Reset Switch

RES

COM

11

12

13

J2

Shieled cable

ground wire

grounded to

remote display

PCB board

Single Channel Pulse Device

• Solid State

Signal Level

• ≥ 2.50 VDC high

• ≤ 2.00 VDC low

Output

• 1.5 mA sinking

Frequency

• 5 kHz maximum

Required Specifications

Single Channel Pulsers

The LectroCount XL LED Remote Display

is supplied with a 30 foot 4-wire shielded

cable with 22 gauge wire. If alternate

cabling is required, Liquid Controls

recommends a similar 4-wire shielded

cable with 22 gauge wire or larger and a

maximum cable length of 30 feet.

Shielded Cable

A jumper is required between terminal 52 and terminal 53 on the display’s J1 terminal block. Display

units from the factory will include the jumper. When rewiring, ensure that this jumper is in place.

J1 Jumper - LectroCount XL LED Remote Display