beautypg.com

Setup – Liquid Controls DMS i1000 EZConnect Operators User Manual

Page 14

background image

14

USB (F3) activates the USB memory device
Done (F5) opens Fueler Logon or Fill Vehicles screen, or DMS

Application List screen

Util (F1) opens System Utilities (1/3) See page 12 EM200-11
Data (F5) opens Database Management screen

#1 -load fleetConnect database

onto the dMs i1000

Liquid Controls recommends using a USB memory

device for the initial loading of the FleetConnect

database because of the large amount of data to be

uploaded. Transmitting a large amount of data wirelessly

can be time consuming and, for cellular transmissions,

costly.

To transfer the latest FleetConnect Office

database to the dMs i1000s via usb device:

1. Using the office PC, name a USB memory device

DMS_

USB and create a folder named DMS in it. (USB memory

devices from Liquid Controls are preconfigured with

these settings.)

2. Copy the .502 and .slf files from the C:\DMS folder into

the D:\DMS_USB\DMS folder on the USB memory

device.

3. Remove the USB memory device from the office

computer and plug it into a DMS i1000.

4. On the DMS i1000 lap pad, push

ALT and ESC

simultaneously to open the

DMS Application

List

.

5. Press

F5 (

Data) to open

Database Management

.

6. Press

F3 (

USB

) to boot the USB Drive.

7. Move the pointer to

Retrieve Entire Database

and push

Enter.

8. Move the pointer to

USB Memory Device

as

the Receive Mechanism and press

Enter. The

Retrieving Database

screen will appear while the

database loads onto the DMS i1000.

9. Press

Enter upon successful retrieval of the database

files.

10. Repeat steps 3-9 until all trucks equipped with DMS

i1000s are loaded with the FleetConnect database.

seTup

The Retrieve Database Updates command inside

the DMS i1000 FleetConnect program will not

upload the whole database, only .502 and .slf files.

Every DMS i1000 is supplied with a USB Flash

Memory Device configured for immediate use.

While the DMS i1000 displays the DMS Application List

screen, it is disabled from the LectroCount register(s).

When the DMS i1000 is disabled, deliveries can be made

with the register’s RUN and PRINT settings.

These instructions are also included in the

FleetConnect Office Setup (EM200-14) manual.

.502 and .slf files are created during FleetConnect

Office setup.

After initial setup, choose

Retrieve Database Updates to

update only those files that have changed. Follow the same

procedure as above, but for step 8, select the

Radio option,

instead of

USB Memory Device, then press Enter.

Transfer Database Wirelessly