30

PoWer InsTallaTIon

Connect the Power

All LCR 600 shipments typically include a 40' gray power cable (100', and 300' are also available) and a 7.5A fuse.

40’ Gray PoWer Cable

The gray power cable (PN 84046) is prewired to the J8 and J9 terminals on the display CPU board and the J6

terminal on the CPU board at the factory. It includes two 16AWG wires and a ground drain wire. The 7.5A fuse should

be spliced into the red 16AWG wire as close to the power source as possible.

ePson PrInTer PoWer

Power must be supplied to the Epson printer as well. A 15' cable with a 12/24VDC converter (825001) for printer

power supply is also available. The red wire of this cable must be spliced into the red wire of the gray power cable on

the LCR 600 side of the 7.5A fuse.

1. Route the gray power cable to the accessory panel. See

page 17

2. Splice the red wire from the printer power cable into the

red wire of the gray power cable.

3. Splice the 7.5A fuse into the red wire. Make the splice

close to the direct power terminal connection in the

accessory panel and on the power side of the splice

made with the printer power cable.

Power Check

After the LCR 600 has been installed, check to make sure that it powers up correctly. The LCR 600 display and the

printer power light should come on when the truck’s ignition is turned to the ON or to the ACC position. Make sure the

printer power switch is on. If the LCR 600 or the printer does not power up, check the wiring and the connections on

the LCR 600 CPU board against the manual.

4. Connect the red wire to the direct power supply terminal

in the accessory panel.

5. Connect the black wire of the gray power cable to a

reliable DC ground.

6. Connect the black wire of the printer power to a reliable

DC ground.

7. Tape the green drain wire of the gray power cable back

against the power cable.

To connect power to the lCr 600 and the epson printer:

Page 17 describes the best practices for routing the gray power cable to the truck cab’s accessory panel.