Valves – Liquid Controls LCR 600 Install User Manual
Page 19

19
valves
Single Stage (S1) Block Valve
Single Stage Electro-Pnuematic
Valve with V-7 Valve
Single Stage
3-Way Valve
Electro-Pnuematic
Preset Valve
A2847-11 Solenoid-Operated
Block Valve
A2859-11 Block Valve
and 3 Way Solenoid
(PN 81527)
single stage systems
liquid Controls’ valves overview
When ordered as part of a meter system with a LCR
600, Liquid Control’s control valves are bolted onto the
meter and wired to the LCR 600 at the factory. Electronic
control valves can also be ordered separately and retrofit
onto meter systems already in service. These valves
will need to be piped and wired in the field. For piping
instructions, refer to the valve manual. This manual
includes wiring instructions for the valves.
In order to control flow, the LCR 600 energizes and
de-energizes solenoid-operated valves on external
bypass piping routed off the main product flow. The
solenoid operated valves close off and open the bypass
pipes. The bypass pipes redirect some of the product
flow in order to open and close the control valve. These
solenoid-operated valves must be wired to the LCR 600
CPU board during installation.
Liquid Controls offers single stage and two stage
electronic valves. Single stage valves have one solenoid
valve (S1) and two positions—an open position and a
closed position. Two stage valves have two solenoid
valves (S1 & S2) and three positions—open, closed, and
dwell flow. Dwell flow is a low flow rate setting controlled
by the S2 solenoid and initiated shortly before the
register reaches a preset value.
sInGle sTaGe valves
The three most common Liquid Controls meter systems
with single stage valves include a block valve with a
S1 solenoid-operated valve fitted onto external piping
(A2847-11), a block valve (A2843) with a 3-way solenoid,
and an electro-pnuematic valve with an S1 solenoid.
A2847-11 Valve
This single stage control valve has a S1 solenoid-
operated valve located at the meeting point of three
pipes: one pipe from the inlet side of the valve, one from
the top of the block valve, and one from the outlet side
of the valve. This valve is typically used in refined fuels
applications.
A2843 Valve and 3-Way Solenoid
The 3-way solenoid-operated valve—mounted directly
to the top center port on the back of the LectroCount
LCR 600—serves as a S1 solenoid-operated valve. The
3-way solenoid-operated valve is located at the meeting
point of two pipes from the vapor eliminator (one for
eliminated vapor and one leading to the spit tank) and
one pipe to the top of the block valve. 3-way solenoid-
operated valves are typically specified for products that
hold vapor in the line such as LPG and NH
3
.
The LCR 600 is also compatible with many other
brands and types of valves.