leCTroCounT lCr 600 MounTInG

LCR 600 Bolt Pattern

LC Meter Compensated

LC Meter

Mounting bolt Pattern

The LectroCount LCR 600 base casting contains eight

bolt holes in an industry standard bolt pattern. The holes

are ½" deep and take ¼"-20 screws.

If the installation necessitates that you fabricate a

bracket, refer to the drawing to the right.

lC Meters

remove existing registration equipment

1. Depressurize the meter completely. See Warning on pg.

14.

2. Remove the four bolts on the bottom that fasten the

register to the meter.

3. Remove the adjuster from the meter.
4. If the meter has a Temperature Volume Compensator

(TVC), remove it as well.

Mount the lectroCount lCr 600

1. Place the end of the shaft adapter on the pulser drive

shaft located on the bottom of the register.

2. Place the cotter pin through the hole, and bend open the

ends of the cotter pin.

3. Lower the register onto the meter, and insert the shaft

adapter onto the hex shaft on the meter.

4. Securely bolt down the register.

Apply anti-seize to all bolt threads to ensure

easy removal at a later date.

Apply Anti-seize