Lectrocount lcr 600 mounting, Mounting bolt pattern, Lc meters – Liquid Controls LCR 600 Install User Manual
Page 15
15
leCTroCounT lCr 600 MounTInG
LCR 600 Bolt Pattern
LC Meter Compensated
LC Meter
Mounting bolt Pattern
The LectroCount LCR 600 base casting contains eight
bolt holes in an industry standard bolt pattern. The holes
are ½" deep and take ¼"-20 screws.
If the installation necessitates that you fabricate a
bracket, refer to the drawing to the right.
lC Meters
remove existing registration equipment
1. Depressurize the meter completely. See Warning on pg.
14.
2. Remove the four bolts on the bottom that fasten the
register to the meter.
3. Remove the adjuster from the meter.
4. If the meter has a Temperature Volume Compensator
(TVC), remove it as well.
Mount the lectroCount lCr 600
1. Place the end of the shaft adapter on the pulser drive
shaft located on the bottom of the register.
2. Place the cotter pin through the hole, and bend open the
ends of the cotter pin.
3. Lower the register onto the meter, and insert the shaft
adapter onto the hex shaft on the meter.
4. Securely bolt down the register.
Apply anti-seize to all bolt threads to ensure
easy removal at a later date.
Apply Anti-seize