9. ADVANCED SETTINGS TAB

Change “Local TCP Port” from its factory default of 502 if that port value is blocked by the
router.

Change “Remote Node UDP Port 2” from its factory default of 63179 if that port value is
blocked by the router. Node discovery will use both Node UDP Port 1 at 63179 and Node UDP
Port 2 at the value set using this screen.

Change “TCP Connection Timeout” from its factory default of 30 seconds if so desired.
Minimum timeout is 16 seconds. Enter 0 to disable timeout. If TCP activity has not been
detected by the Node for this timeout, the TCP connection is broken by the Node.

Press on “Put” to save your port and timeout changes in the Node.

Click on “Read Node Setup File” to retrieve a previously saved Node setup file from disk.
This is a convenience feature if multiple Nodes have to be set up the same way. Click on “Write
Node Setup File” to save your current Node setup to a disk file.

Enter the Static IP Address, Gateway and Subnet Mask if these are not supplied by a DHCP
server.