(0x47) Set Communication
The Set Communication command can be used two different ways. The first method
is a direct one-to-one communication with a single SeaI/O module. This requires a
Get Config request to obtain the Magic Cookie byte. However, to easily change the
communication parameters of multiple SeaI/O modules at the same time, the Set
Communication operation can be broadcast to all daisy-chained modules. A sample
transaction is shown with an assumed Magic Cookie byte of 0xCA, which is only
required for one-to-one communication.
Request
Response
Field Name
(Hex)
Field Name
(Hex)
Function
47
Function
47
Baud Rate
0A
Baud Rate
0A
Parity
00
Parity
00
Magic Cookie
CA
Magic Cookie
CA
Upon a successful Set Communication operation, the SeaI/O module will respond
with the same packet it received. An exception can be generated if one of the
following conditions occurs:
•
The baud rate is not within the range [1, 0A] (Hex)
•
The parity rate is not within the range [0, 2]
•
The Magic Cookie is invalid (one-to-one communication only)