Impulse 463E User Manual
Page 20
© Sealevel Systems, Inc.
- 17 -
SeaI/O User Manual
Sample Power Calculation
A typical application for SeaI/O products would use one Base module and several N-
series units in a local expansion configuration. In this arrangement, with power
applied to the Base module through either the DC jack or screw terminal connector
and passed-through to the expansion units, attention should be given to ensure the
input power to the Base module is adequate.
Example:
Power
(W)
Base Unit:
SeaI/O-430U
0.7
Expansion 1:
SeaI/O-410N
1.4
Expansion 2:
SeaI/O-440N
2.5
4.6W
Power
Required
In this application, the Sealevel Item# TR112 “wall wart” power supply is a good
choice since it is low-cost and supplies 24VDC @ 250mA (6W).
NOTE:
A complete listing of recommended power supplies is provided in
the Accessories section of this manual.
- PCW-5181 (120 pages)
- PCM-4373 (2 pages)
- EPIC-5536 (2 pages)
- EPIC-CV07 (2 pages)
- EPIC-QM57 (2 pages)
- EPIC-QM77 (2 pages)
- VSX-6118-V2 (1 page)
- VSX-6116-V2 (1 page)
- VSX-6115-V2 (1 page)
- VSX-6114-V2 (1 page)
- VDX-6318RD (1 page)
- VDX-6316RD (1 page)
- VDX-6315RD (1 page)
- VDX-6314RD (1 page)
- PCM-5895 Rev. A (2 pages)
- PCM-8120 (2 pages)
- PCM-9562 (3 pages)
- VSX-6127-V2 (1 page)
- PCM-9375 (3 pages)
- GENE-5315W1 Rev. B (2 pages)
- GENE-5315 Rev. A (2 pages)
- VDX-6327RD (1 page)
- VDX-6328RD (1 page)
- VDX-6329RD (1 page)
- VDX-6326RD (1 page)
- PCM-9343 (3 pages)
- GENE-9655 (2 pages)
- PCM-9362 (2 pages)
- GENE-LN05W2 Rev. B (2 pages)
- PCM-9363 (3 pages)
- GENE-TC05W2 (2 pages)
- GENE-CV05W2 (2 pages)
- SBC-210 (1 page)
- GENE-QM57 (2 pages)
- GENE-QM67 (2 pages)
- GENE-QM77 Rev B (2 pages)
- GENE-QM77 Rev A (2 pages)
- GENE-QM87 (1 page)
- EL630-NR (2 pages)
- EL620-C (2 pages)
- SB601-C (2 pages)
- SB600-C (2 pages)
- SB630-CRM (2 pages)
- CL630-CRM (2 pages)
- DL631-C226 (2 pages)