beautypg.com

2 control wiring, Important – Controlled Products Systems Group 6300-080 User Manual

Page 29

background image

6300-065-Z-7-12

27

5.2 Control Wiring

3-Wire

Radio Receiver

Limited to 250 ma.

Power (24 Volt DC) and
logic output. Power is
shut off .5 sec. prior to
gate starting and remains
off while gate is opening
and in the open position.

Convenience Open Radio

Receiver Note:

Wiring may differ.

See section 7.1 on page 33

for more info.

Com

Relay

Red Open

Green Close

White Com

24 V

o

lt

Com

Com

Key Switch

Stand-Alone
Keypad

Stand-Alone
Card Reader

Telephone
Entry

Note: All stand-alone and
telephone entry devices must
use a separate power source.

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

NC

NO

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

Magnetic Lock

3-Button Station

DoorKing ONLY

SW 1

SW 2

SW 1, switch 3 must be ON.

#12 - Safety

Opening Device

Radio
Open

Access
Device
Open

Safety
Open

#11 - Access Control

Devices

Com

Com

(2) Two 115 VAC
Convenience Outlets

SW 1

1

ON

2

3

4

5

6

7

8

Important:

Controls must be installed

a minimum of 10-feet from the gate or
installed in such a way that the person
using the control cannot come in
contact with the gate or gate operator.

24 Volt

1 amp max.

Coax Antenna Kit
P/N 1514-073

Antenna mounted
outside operator cover.

This manual is related to the following products: