2 control wiring, Important – Controlled Products Systems Group 6300-080 User Manual
Page 29
6300-065-Z-7-12
27
5.2 Control Wiring
3-Wire
Radio Receiver
Limited to 250 ma.
Power (24 Volt DC) and
logic output. Power is
shut off .5 sec. prior to
gate starting and remains
off while gate is opening
and in the open position.
Convenience Open Radio
Receiver Note:
Wiring may differ.
See section 7.1 on page 33
for more info.
Com
Relay
Red Open
Green Close
White Com
24 V
o
lt
Com
Com
Key Switch
Stand-Alone
Keypad
Stand-Alone
Card Reader
Telephone
Entry
Note: All stand-alone and
telephone entry devices must
use a separate power source.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
NC
NO
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
Magnetic Lock
3-Button Station
DoorKing ONLY
SW 1
SW 2
SW 1, switch 3 must be ON.
#12 - Safety
Opening Device
Radio
Open
Access
Device
Open
Safety
Open
#11 - Access Control
Devices
Com
Com
(2) Two 115 VAC
Convenience Outlets
SW 1
1
ON
2
3
4
5
6
7
8
Important:
Controls must be installed
a minimum of 10-feet from the gate or
installed in such a way that the person
using the control cannot come in
contact with the gate or gate operator.
24 Volt
1 amp max.
Coax Antenna Kit
P/N 1514-073
Antenna mounted
outside operator cover.