beautypg.com

4 pad mount, 3 underground conduit requirements – Controlled Products Systems Group 6300-080 User Manual

Page 14

background image

6300-065-Z-7-12

12

9.5”

6”

1.4 Pad Mount

Open Gate

Closed Gate

3”

3”

1.5”

1.5”

3”

90°

Depth of the concrete pad is
determined by soil conditions and
local building codes. Reinforced
concrete recommended.

Note: If allowed by local codes, the
top of the concrete pad can be flush
with ground level, which will allow
the gate bracket to be mounted
lower on the gate.

Low
Volt

Arm

Rotation

Area

High
Volt

Gate Bracket Height

Concrete Pad Position

3/8

Secure the operator to the
concrete pad with six (6)
3/8” x 3” sleeve anchors
(not supplied).

Operator MUST be level.

Interconnection

Cable

Note: Right support leg removed from
this illustration to show conduit detail.

Pad Support

Base

Output
Shaft

5”

11”

Note: 2” thick

gate Illustrated.

Important Note:

These pad mount measurements will

ONLY work when the operator is positioned using the

“1.1 Operator Position”

measurements on page 10.

16.5”

30”

23”

Concrete Pad

43”

12”

14”

10”

Conduit

1.3 Underground Conduit Requirements

Sweeps

Concrete Pad

Primary

Operator

Position

Secondary

Operator

Position

• The conduit requirements are for a typical slide gate operator installation (the secondary operator is shown for
those applications where a secondary operator may be used). The conduit requirements for your application may
vary from this depending on your specific needs.

• Use only sweeps for conduit bends. Do not use 90° elbows as this will
make wire pulls very difficult and can cause damage to wire insulation.

• DoorKing recommends using 3/4-inch conduit.

• Be sure that all conduits are installed in accordance with local codes.

Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation.

Elbow

NO

Sweep

YES

Control and/or P.A.M.S. Wires (Low Voltage wire insulation)

DoorKing’s Primary/Secondary Interconnection Cable (Dual Operator Application Only)

(Secondary Operator AC Power and Communication wires)

Loop Lead-In Wires (Low Voltage wire insulation)

AC Input Power (High Voltage wire insulation)

This manual is related to the following products: