Limits, Limits -54 – CONTREX MLP-Trim User Manual
Page 94

3 - 54
Limits
The MLP-Trim has the ablity to limit both the minimum and maximum operating speed
when in the Run state.
The following control parameters are used by the MLP-Trim for limit control:
Minimum Limit (CP-08)
This parameter sets the minimum level of operation in the Run state. It
is possible to enter a setpoint below this limit, however, the control will
always attempt to maintain a speed at or above this RPM level.
Maximum Limit (CP-09)
This parameter sets the maximum level of operation in the Run state. It
is possible to enter a setpoint above this limit, however, the control will
always attempt to maintain a speed at or below this RPM level.
Table 3-45 Default Limit Control Parameters
CP
Parameter Name
Parameter Value
CP-08
Minimum Limit
0
CP-09
Maximum Limit
2000
Table 3-46 Entering Limit Control Parameters
CP
Parameter Name Parameter Value
CP-08
Minimum Limit
CP-09
Maximum Limit
Enter the desired minimum operating RPM.
Enter the desired maximum operating RPM.