CONTREX MLP-Trim User Manual
Page 64

3 - 24
Table 3-17 Follower Mode Control Parameters Example A
CP
Parameter Name
Parameter Value
CP-33
Max RPM Lead
1725
CP-34
Max RPM Feedback
1800
CP-30
PPR Lead
60
CP-31
PPR Feedback
30
CP-21
Follower E.U.
3.00
CP-03
Follower Setpoint 1
3.00
CP-04
Follower Setpoint 2
4.50
The MLP–Trim will adjust and monitor the speed of the Follower motor to achieve the
desired gallons/minute. This completes the scaling and setpoint information for
Example A. Example B is discussed in the following section.