3 - 72
MP-57 EEPROM STATUS
The Control Parameters are stored in the EEPROM memory chip. EEPROM Status
(MP-57) displays the status of the EEPROM memory chip. The number “0” indicates
no failure. The number “1” indicates a write verify error. In the event of an error, call
Technical Support at (612) 424-7800 or 1-800-342-4411.
MP-59 FREQUENCY OVER FLOW COUNTER
The Frequency Over Flow Counter (MP-59) is a counter that increments each time the
frequency input to the MLP–Trim causes an overflow. To reset the counter to “0”, press
the Clear key.
MP-83 LIMIT STATUS
Limit Status (MP-83) displays the status of the Minimum Limit (CP-08) and the
Maximum Limit (CP-09) functions. A "1" in the display digit location for the respective
function indicates that function is limiting.
Not Used
Min Limit
Max Limit
Not Used
Code