beautypg.com

Ection – Clear-Com WTR-680 User Manual

Page 67

background image

Sys tem Walk-Thru

Now that you have suc cess fully “set-up” your Wire less In ter -
com Sys tem and turned on any aux il iary equip ment, you are
ready to test the over all per for mance by “Walking” the sys tem
through the ar eas in which you will be us ing it.

Be fore you be gin your walk-thru, check the fol low ing:

Beltpack Bat tery Check.

Set mi cro phone gain in both the beltpack(s) and the
base sta tion.

The base sta tion and beltpack(s) are on the same group
and the beltpack(s) are on their own unique trans port
chan nels that match the base sta tion re ceive chan nels

Check that the talk but ton is en gaged. The talk LED
will be il lu mi nated.

In ter com Level “IN” and “OUT” are set to an ap pro -
pri ate level.

Aux il iary Level “IN” and “OUT” are set to an ap pro -
pri ate level (if used).

The “sys tem walk-thru” can de tect prob

lem of weak sig nal

strength caused by:

Poor an tenna lo ca tion

Wrong an tenna for re ceiver and/ or trans mit ter

RF “Trou ble Spots”

Op er ating dis tance be yond sys tem ca pa bil ity

Old or used bat ter ies in the WTR-680

Un der nor mal con di tions the base sta tion’s dis play will in di cate
a beltpack sta tus. “Weak Sig nal” con di tion will re sult in “no tx”
be ing dis played on the base sta tion’s re ceiver for that beltpack.

In 99% of all in stances you will set up your Wire less In ter com
Sys tem, walk it through the area of in ter est and achieve er -
ror-free per for mance. If in the rare in stance your sys tem does
not “pass” dur ing your walk-thru eval u a tion, re fer to the sec -
tion of this man ual which deals with Sys tem Trou ble shooting.

8-1

S

ection

8

This manual is related to the following products: