Dual Lis ten Func tion al ity

The base sta tion’s main au dio board has the op tion of plac ing
ad di tional parts to en able dual lis ten. Dual lis ten al lows the
mix ing of the in ter com chan nels. The mix ing will oc cur lo -
cally, within the base sta tion, and is only heard on that base
sta tion's beltpacks. The user will have the abil ity to en able/dis -
able the mix of I/C A into I/C B or vise versa.

They will also have the abil ity to con trol the level of the mix
(-4 dB to -24 dB down from main chan nel). Re moving two
sur face mount re sis tors and in stall ing two SPDT switches and
two po ten ti om e ter en ables dual lis ten. The parts to be in stalled
are shown in Ta ble 1. The two re sis tors on the board to be re -
moved are in Ta ble 2.

Ta ble 1

Parts to be In stalled by User to En able Dual Lis ten

Ta ble 2

Parts to be Re moved by User to En able Dual Lis ten

The listed man u fac tures and part num bers in Ta ble 1 are those
that the au dio board was laid out for and thus the hole pat tern
used. Sev eral of these parts may be found at Digi-Key and
other dis trib u tors. Trim the leads on the parts so they can not
hit the metal case. Lo ca tions to place these com po nents are
pro vided on au dio board part num ber 750608.

The au dio board part num ber is lo cated on the lower left hand
side of the board if fac ing the front of the unit. The lo ca tions
where the com po nents can be in stalled are on the up per right
hand side of the board. See Fig ure 21 for the lo ca tions.

Fig ure 21

Au dio Board Part Num ber and Dual Lis ten Com po nent Lo ca tions

5-7

Board

Des ig na tor

De scrip tion and Func tion

Value

Man u fac turers, Part No.

VR5, VR6

Po ten ti om e ters

20kW - 25kW

Bourns, 3309P-1-203

VR5 = Con trols I/C A into I/C B Mix

CTS, U262R253B

VR6 = Con trols I/C B into I/C A Mix

Piher, PT10LV10-203A2020

S6, S7

Switches

SPDT

E-Switch, 500ASSP1M2RE

S6 = En able/Dis able I/C A into I/C B Mix

E-Switch, EG1218

S7 = En able/Dis able I/C B into I/C A Mix

Alcoswitch, TSS11DGPC

Board

Des ig na tor

De scrip tion and Func tion

Value

R295

Re sis tor, De fault if mix com po nents not in stalled

10k

R296

Re sis tor, De fault if mix com po nents not in stalled

10k

FRONT

BACK

B INTO A

MIX

OFF

ON

ON

IF PARTS INSTALLED

REMOVE R296

S7

S6

R

2

9

6

R

2

9

8

V

R

6

MIX

LEVEL

OFF

ON

ON

IF PARTS INSTALLED

REMOVE R295

R

2

9

5

R

2

9

7

V

R

5

MIX

LEVEL

A INTO B

MIX

B INTO A

MIX

OFF

ON

ON

IF PARTS INSTALLED

REMOVE R296

S7

S6

R

2

9

6

R

2

9

8

V

R

6

MIX

LEVEL

OFF

ON

ON

IF PARTS INSTALLED

REMOVE R295

R

2

9

5

R

2

9

7

V

R

5

MIX

LEVEL

A INTO B

MIX

750608 REV X
879416- 1 REV J

750608 REV X
879416- 1 REV J

This manual is related to the following products: