4 - 3
TEMPERATURE
Operating
between 0 and 50 C (32 to 125 F)
Storage
between 0 and 70 C (32 to 150 F)
HUMIDITY
Operation and Storage
Between 20% and 90%,
Non-Condensing
PACKAGE DIMENSIONS
Height
3.5 in. (8.89 cm), (2 RU, EIA rack)
Width
19.0 in. (48.26 cm)
Depth
6.75 in. (17.15 cm)
Weight
7.5 lbs. (4.0 kg)
OPT-100 AUXILIARY AUDIO I/O OPTION
AUDIO
Output Signal Levels
0.0 dBu nominal
Impedance
600 Ohms, transformer balanced
Frequency Response
100 Hz to 10 kHz, +/- 2 dB of
microphone preamp or external
program input
Distortion
Less than 0.5% THD
SA RELAY
Contact Type
1 pair SPDT (single form C)
Contact Voltage Rating
24 VDC
Contact Current Rating
1 Amp continuous, 2 Amps peak at 24
VDC