9. Replace the panel.

• The operator cannot hear another panel’s page or call signal

tones.

1. Adjust the “Page Volume” control of the panel using the

configuration program (refer to the Eclipse Configuration System
Manual

).

2. Check the panel’s configuration to see if page override is enabled.

• Announce tones (eavesdropping indication, change tones, etc.)

aren’t heard at the panel.

Check the configuration program to see if the monitoring tones and
change tones are enabled.

• No speaker audio from the external program feed.

1. Check the “Program” knob on the panel’s front panel.
2. Check the program source.
3. Reset the panel.
4. Replace the panel.

• The headphone isn’t receiving audio from the external program

feed.

1. If the external program feed is audible in the speaker, check the

panel’s configuration program to ensure the program was not

disabled for the second earphone feed.

2. Replace the panel.

• Accessory panels do not function.

1. Check the accessory panel’s connection on the panel’s rear panel.
2. Ensure the external AC power transformers are correctly connected

to the accessory panels.

3. Check the configuration program to ensure the correct number of

selectors are configured.