System configuration menu – Clear-Com ICS-2003 User Manual
Page 19

Clear-Com Communication Systems
ICS-2003 Intercom Panel Instruction Manual
1 - 1 1
Warning: All panel key reassignments take place immediately
upon exiting this function. Active talk and listen paths
will be disconnected when their labels are removed.
System Configuration Menu
The System Configuration menu changes some of the Eclipse System
configuration parameters typically only available through the
configuration program. These are:
• Assign Party Line Members
• Assign Fixed Group Members
• Assign Panel Keys
• Assign Forced Listens
• Change Input Level Gains
Assign Party Line Members
To add or remove an interface from a party line:
1. Choose the appropriate interface label category.
2. Choose an interface label.
3. A list of available party lines will be displayed. If the label is currently
part of any displayed party line, that party line(s) will be outlined.
Add or delete the label from a displayed party line by selecting it and
pressing Enter.
Assign Fixed Group Assignments
To add or remove panels or interfaces from fixed groups:
1. Choose the appropriate interface label category.
2. Choose an interface label.
3. A list of available fixed groups will be displayed. If the label is
currently part of any displayed fixed group, that fixed group(s) will be
outlined. Add or delete the label from a displayed fixed group by
selecting it and pressing Enter.
Assign Panel Keys
To change the talk and listen selector labels on any panel in the
system, including the selectors on accessory panels:
1. Choose a panel.
2. Choose the selector to be assigned.
Note:
It may be necessary to select a talk/listen window or
expansion panel if the selector to be assigned isn’t visible. Use the
Pg Up and Pg Dn buttons for this.
3. Press the Enter button to display all labels available for assignment.
4. Select the desired label.
To select between talk keys, listen keys, and combo keys:
Some panels support keys which may be talk, or listen, or talk with
listen, sometimes called combo keys. To change between these
assignments on these panels use the keypad keys “2” or “up” and
“8” or “down.” If the selected key is shown on the top line of the