Clear-Com HX System Frames User Manual
Page 74
Important note:
Figure 22 shows an unconfigured E-MADI64 card , when all lights are lit to indicate their location.
On a card with a clock source and MADI connections ( where the received MADI signal matches the
card set up), the following lights are lit: the Lock source LED [ ], the Sample rate (Fs) LED
[ ], the Channels LED [ ] and the Active LED [ ]. The Error LED [ also ] is lit when
there is no clock source or MADI input.
Key to Figure 22: E-MADI64 front panel lights and controls
Feature
Description
A
Reset button
Pressing the Reset button causes the card and all links to momentarily stop
their current activity and to restart. The
flashing green
Active light goes off
when the reset starts and comes back on when the reset is complete.
During the reset, configuration information downloads to the card and its
connected matrices from the CPU card. If the entire system is operating
except for one E-MADI64 card, press the reset button for that card only.
Tip:
The reset button is slightly recessed from the front panel to prevent it
from being accidentally pressed. A tool such as a bent paper clip is needed to
press this button.
B
+3.3-Volt Power Supply LED
The matrix +3.3-volt power supply provides electric current to this
green
light.
When lit, the light indicates that the +3.3-volt supply is present and supplying
electric current to the card.
C
Lock source
A
green
light indicates that the E-MADI64 card has locked to the clock source
(either video (VID) or Word Clock (WRD)).
C
D
E
F
F
74