5 ivc-32 ip interface card, Ivc-32 redundant card, Ivc-32 ip interface card – Clear-Com HX System Frames User Manual
Page 20
Each E-MADI64 card set comprises:
• A front card with pin reset and various status indicators (including channel quantity,
sample rate, power and diagnostic (active and error) indicators).
• A rear card with a MADI fiber connector, MADI input and output coaxial cable
connectors, and coaxial Video / Word clock input.
Tip:
A total of four E-QUE, IVC-32 or LMC-64 interface cards may be fitted to an Eclipse
HX-Omega. For the order in which all interface cards must be installed to the Eclipse HX-
Omega, see 4.4 Installing interface cards.
Note:
Cards slide vertically into the front of the matrix and connect to the backplane.
3.4.5 IVC-32 IP interface card
The IVC-32 interface allows the Eclipse matrix to connect to IP enabled V-Series panels,
other matrices and Concert users via an IP network.
Each IVC-32 interface comprises:
• A front card with a reset button and various status indicators.
• A rear card with eleven RJ-45 ports giving eight E1/T1 ports (not used), DECT sync
in and out (not used) and a LAN port for IP connectivity.
Each IVC-32 front card has status LEDs for power, port activity and LAN status. The LAN
indicators show whether there is a LAN connection and the IP activity on the LAN port.
Tip:
A total of four E-QUE, IVC-32 or LMC-64 interface cards may be fitted to an Eclipse
HX-Omega. For the order in which interface cards must be installed to the Eclipse HX-
Omega, see 4.4 Installing interface cards.
Note:
Cards slide vertically into the front of the matrix and connect to the backplane.
IVC-32 Redundant Card
You can add an IVC-32 Redundant Card that provides fail-over redundancy for one or more IVC-32
Cards in the matrix.
An IVC-32 Card will fail-over to the IVC-32 Redundant Card under the following conditions:
• • All configured
VoIP
ports are unconnected for longer than 90 seconds.
• • The IVC-32 Card is detected as absent from the VME backplane.
• • It is requested
via
the EHX Event Log.
A switch back from a redundant card back to a failed card only occurs under the following condition:
• The redundant card has failed. If the original card is still in error, then it will switch back and
forward until corrective action is taken.
20
Eclipse HX-Omega User Guide