background image


PSU1 Fail

When the first power supply unit is operating correctly, the

red

PSU1 light stays off, while

the four

green

power supply lights (+12V, +5V, +3.3V, -12V) stay on continuously.

If a DC output or AC input to the first power supply drops too low, the

red

PSU1 light

switches on. The

amber

(XP) or

red

(Power-One) light on the power supply unit itself also

switches on to indicate the same condition. One of the green power supply lights may then
switch off to help indicate the source of the trouble.

Note:

The PSU1 fail light only works if the first power supply is plugged into the matrix’s midplane
from inside the matrix.

A temperature sensor inside the power supply senses if the power supply overheats, and
switches on the second matrix cooling fan. The

red

Temp light switches on to indicate that

the active CPU card, not a power supply, has overheated.

PSU2 Fail

When the first power supply unit is operating correctly, the

red

PSU2 light stays off, while

the four

green

power supply lights (+12V, +5V, +3.3V, -12V) stay on continuously.

If a DC output or AC input to the first power supply drops too low, the

red

PSU2 light

switches on. The

amber

(XP) or

red

(Power-One) light on the power supply unit itself also

switches on to indicate the same condition. One of the green power supply lights may then
switch off to help indicate the source of the trouble.

Note:

The PSU2 fail light only works if the first power supply is plugged into the matrix’s midplane
from inside the matrix.

A temperature sensor inside the power supply senses if the power supply overheats, and
switches on the second matrix cooling fan. The

red

Temp light switches on to indicate that

the active CPU card, not a power supply, has overheated.

Fan-On alarm light

Two fans deliver forced air cooling to the matrix’s power supplies. The primary fan runs
continuously. If a temperature exceeding a threshold is detected in a power supply and extra
cooling is required, a second fan switches on to increase the air flow.

The fan-on alarm light illuminates

red

to indicate that the second fan is on.

5.8.5 Power Supply Lights

The

green

power-supply lights illuminate to indicate that the power supplies are receiving

+12 V, –12 V, +5 V, and 3.3 V power.