Performance data sheet – Hydrotech 6200 SXT Automatic Meter Initiated Water Softener User Manual
Page 4

3
Performance Data Sheet
Unit Item #
2400
2401
2402
2403
2404
2405
2406
Model #
HSC75
HSC10
HST75
HST10
HST15
HST20
HST25
Tank Size
9 x 35
10 x 35
8 x 44
9 x 48
10 X 54
12 X 52
14 X 50
Media (CF)
0.75
1
0.75
1
1.5
2
2.5
Service Flow Rate (gpm)
8
9
8
10
12
13
13
Total Softener Capacity (10lbs of salt/CF of Resin)
21,400
30,000
21,400
30,000
45,000
60,000
75,000
Capacity* - 6 lbs salt/CF of Resin (Efficiency)
13,900 (3,100) 18,526 (3,087) 16,680 (3,100) 18,526 (3,087) 21,026 (3,504) 24,780 (4130) 30,975 (4,130)
Capacity* - 3 lbs salt/CF of Resin (Efficiency)
9,292 (4,100)
12,390 (4,128) 11,150 (4,100) 12,390 (4,128) 13,016 (4,338) 13,960 (4653) 17,450 (4,130)
Capacity* - 2 lbs salt/CF of Resin (Efficiency)
6,717 (4,497)
8,957 (4,497)
8,060 (4,497) 8,957 (4,497) 9,236 (4,618)
9,660 (4830)
12,075 (4,130)
Capacity (Theoritical) @ 6 lbs of Salt/CF of Resin
13,500
18,000
13,500
18,000
27,000
36,000
45,000
Capacity (Theoritical) @ 3 lbs of Salt/CF of Resin
6,750
9,000
6,750
9,000
13,500
18,000
22,500
Backwash Flow Rate (gpm)
1.5
2
1.5
2
2.4
4
4.5
Injector Size
#00
#00
#00
#00
#00
#00
#0
Brine Line Flow Control (gpm)
0.125
0.125
0.125
0.125
0.25
0.25
0.5
Slow Rinse Flow Rate (gpm) @ 40 psi inlet pressure 0.25
0.25
0.25
0.25
0.25
0.25
0.25
Regneration Time Steps @ 6 lbs salt/CF of Resin
6
6
6
6
6
6
6
Brine Draw & Slow Rinse Time (Minutes)
25
33
25
33
41
60
60
Backwash Time (Minutes)
5
5
5
5
5
5
5
Rapid Rinse Time (Minutes)
5
5
5
5
5
5
5
Brine Refill Time (Minutes)
12
16
14
16
12
16
8
Total Regen Time (6 lbs/CF) Minutes
47
59
47
59
61
86
82
Regneration Time Steps @ 3 lbs salt/CF of Resin
3
3
3
3
3
3
3
Brine Draw & Slow Rinse Time (Minutes)
19
25
19
25
31
50
60
Backwash Time (Minutes)
5
5
5
5
5
5
5
Rapid Rinse Time (Minutes)
5
5
5
5
5
5
5
Brine Refill Time (Minutes)
6
8
7
8
5
8
5
Total Regen Time (3 lbs/CF) Minutes
35
43
35
43
46
68
76
Regneration Time Steps @ 2 lbs salt/CF of Resin
2
2
2
2
2
2
2
Brine Draw & Slow Rinse Time (Minutes)
17
23
17
23
29
46
60
Backwash Time (Minutes)
5
5
5
5
5
5
5
Rapid Rinse Time (Minutes)
5
5
5
5
5
5
5
Brine Refill Time (Minutes)
4
5
5
5
3
5
4
Slow Rinse Flow Rate (gpm) (Minutes)
0.25
0.25
0.25
0.25
0.25
0.25
0.25
Total Regen Time (2 lbs/CF) Minutes
31
38
31
38
42
61
74
Regen Water Consumed - 6 lbs salt/CF - Gallons
23
30
23
30
33
49
69
Regen Water Consumed - 3 lbs salt/CF - Gallons
20
27
20
27
29
45
66
Regen Water Consumed - 2 lbs salt/CF - Gallons
20
26
20
26
28
43
57
Conv. Regen Water - 6 lbs salt/CF - Gal
47
57
47
57
58
79
109
% Difference in Regen Water Saving
51%
47%
51%
47%
43%
38%
37%
* Manufacturer's internal testing based on NSF 44 Standard method