beautypg.com

Performance data sheet – Hydrotech 6200 SXT Automatic Meter Initiated Water Softener User Manual

Page 4

background image

3

Performance Data Sheet

Unit Item #

2400

2401

2402

2403

2404

2405

2406

Model #

HSC75

HSC10

HST75

HST10

HST15

HST20

HST25

Tank Size

9 x 35

10 x 35

8 x 44

9 x 48

10 X 54

12 X 52

14 X 50

Media (CF)

0.75

1

0.75

1

1.5

2

2.5

Service Flow Rate (gpm)

8

9

8

10

12

13

13

Total Softener Capacity (10lbs of salt/CF of Resin)

21,400

30,000

21,400

30,000

45,000

60,000

75,000

Capacity* - 6 lbs salt/CF of Resin (Efficiency)

13,900 (3,100) 18,526 (3,087) 16,680 (3,100) 18,526 (3,087) 21,026 (3,504) 24,780 (4130) 30,975 (4,130)

Capacity* - 3 lbs salt/CF of Resin (Efficiency)

9,292 (4,100)

12,390 (4,128) 11,150 (4,100) 12,390 (4,128) 13,016 (4,338) 13,960 (4653) 17,450 (4,130)

Capacity* - 2 lbs salt/CF of Resin (Efficiency)

6,717 (4,497)

8,957 (4,497)

8,060 (4,497) 8,957 (4,497) 9,236 (4,618)

9,660 (4830)

12,075 (4,130)

Capacity (Theoritical) @ 6 lbs of Salt/CF of Resin

13,500

18,000

13,500

18,000

27,000

36,000

45,000

Capacity (Theoritical) @ 3 lbs of Salt/CF of Resin

6,750

9,000

6,750

9,000

13,500

18,000

22,500

Backwash Flow Rate (gpm)

1.5

2

1.5

2

2.4

4

4.5

Injector Size

#00

#00

#00

#00

#00

#00

#0

Brine Line Flow Control (gpm)

0.125

0.125

0.125

0.125

0.25

0.25

0.5

Slow Rinse Flow Rate (gpm) @ 40 psi inlet pressure 0.25

0.25

0.25

0.25

0.25

0.25

0.25

Regneration Time Steps @ 6 lbs salt/CF of Resin

6

6

6

6

6

6

6

Brine Draw & Slow Rinse Time (Minutes)

25

33

25

33

41

60

60

Backwash Time (Minutes)

5

5

5

5

5

5

5

Rapid Rinse Time (Minutes)

5

5

5

5

5

5

5

Brine Refill Time (Minutes)

12

16

14

16

12

16

8

Total Regen Time (6 lbs/CF) Minutes

47

59

47

59

61

86

82

Regneration Time Steps @ 3 lbs salt/CF of Resin

3

3

3

3

3

3

3

Brine Draw & Slow Rinse Time (Minutes)

19

25

19

25

31

50

60

Backwash Time (Minutes)

5

5

5

5

5

5

5

Rapid Rinse Time (Minutes)

5

5

5

5

5

5

5

Brine Refill Time (Minutes)

6

8

7

8

5

8

5

Total Regen Time (3 lbs/CF) Minutes

35

43

35

43

46

68

76

Regneration Time Steps @ 2 lbs salt/CF of Resin

2

2

2

2

2

2

2

Brine Draw & Slow Rinse Time (Minutes)

17

23

17

23

29

46

60

Backwash Time (Minutes)

5

5

5

5

5

5

5

Rapid Rinse Time (Minutes)

5

5

5

5

5

5

5

Brine Refill Time (Minutes)

4

5

5

5

3

5

4

Slow Rinse Flow Rate (gpm) (Minutes)

0.25

0.25

0.25

0.25

0.25

0.25

0.25

Total Regen Time (2 lbs/CF) Minutes

31

38

31

38

42

61

74

Regen Water Consumed - 6 lbs salt/CF - Gallons

23

30

23

30

33

49

69

Regen Water Consumed - 3 lbs salt/CF - Gallons

20

27

20

27

29

45

66

Regen Water Consumed - 2 lbs salt/CF - Gallons

20

26

20

26

28

43

57

Conv. Regen Water - 6 lbs salt/CF - Gal

47

57

47

57

58

79

109

% Difference in Regen Water Saving

51%

47%

51%

47%

43%

38%

37%

* Manufacturer's internal testing based on NSF 44 Standard method