User Programming Mode Steps

Note: Use

and

Down button to adjust values for parameters

1. Press the

and

buttons for five seconds while in service, and the time of day is NOT set to 12:01 PM.

2. Use this display to adjust the Day Override. Adjust this to OFF parameter for softeners.

3. Press the

button. Use this display to adjust the Regeneration Time.

4. Press the

button. Use this display to adjust the Feed Water Hardness in grains per gallon (gpg).

Hardness Compensation
1 mg/l of iron = 4 gpg
1 mg/l of manganese = 8 gpg
Maximum iron is not to exceed 1.5 mg/l total iron
Recommend the addition of a Res-up feeder when the total iron exceeds 0.5 mg/l

5. Press the

button. Use this display to adjust the Fixed Reserve Capacity. This option setting is

identified by “RC” in the upper left-hand corner of the screen. 75 gallons X # of people in the
house = RC

6. Press the

button. Use this display to set the Current Day of the Week. This option setting is

identified by “CD” in the upper left hand corner of the screen. This option is only available after the
Day of the Week control is set to ‘ON’ in the Master Programming. Refer to the valve manual for
details.

7. Press the

button to end User Programming Mode.

Programming Instructions

Set Time of Day

Press and hold or buttons until display reads TD

Adjust the displayed time with or buttons. Press to resume normal operation

Queuing a Regeneration

1. Press the button. The service icon will flash to indicate that a regeneration is queued.

2. To cancel a queued regeneration, press the button.

Regenerating Immediately

Press and hold the button for five seconds.

User Programming Mode Options

Abbreviation

Parameter

Description

DO

Day Override

The timer’s day override setting

THIS IS An OPTIOn OnLY. PLEASE DO nOT ADjUST BEFORE COnSULTInG An AUTHORIzED DEALER.

RT

Regeneration Time

The time of day that the system will regenerate (meter delayed, timeclock, and day-of-week systems)

H

Feed Water Hardness The hardness of the inlet water - used to calculate system capacity for metered systems

RC

Reserve Capacity

The fixed reserve capacity

CD

Current Day

The current day of week

OFF

OFF

OFF

OFF

OFF

In the second level mode, the control valve has been pro-
grammed as per the following main parameters related to
regeneration. For more information on master programming
manual, read control valve manual part # 54802

The valve has been pre-programmed with factory settings
as shown in the following chart:

Regeneration Cycle Step Programming

1. Brine Rinse

60 minutes

2. Backwash

10 minutes

3. Rapid Rinse

10 minutes

4. Brine Refill

12 minutes

16 minutes

10 minutes

16 minutes

12 minutes

HSC75/HST75

HSC10/HST10

HST15

HST20

HSC25