beautypg.com

Hydrotech 6200 SXT Automatic Meter Initiated Water Softener User Manual

Page 31

background image

30

Servicing 6200 SXT Upflow Control Valve – Replacing Injectors and Screen

Vortex
Generator

Disperser

Vortex
Generator

Screen

Two
O-Rings

Disperser

Screw

Disperser

Gasket

Valve Body

Screen

Injector
Cap

Injector
Assembly

1. Unscrew the injector cap from the valve body

2. Discard gasket

3. Remove injector assem-

bly from the valve body
and discard it.

4. Apply silicone lubricant

to the gasket and install
around oval extension on
injector cap

5. Apply silicone lubricant to

two new o-rings and install
over 2 bosses of the new
injector assembly.

6. Apply silicone grease to

the dispersor and press
it on the surface of the
injector assembly.

7. Screw in new injector

throat and nozzle (make
sure that vortex generator
is installed in the injector
body), be sure they are
seated tightly.

8. Install a new screen.
9. Tighten injector cap on
to the valve body