beautypg.com

Water softener sanitization – Hydrotech 6200 SXT Automatic Meter Initiated Water Softener User Manual

Page 17

background image

16

19. Set time of the day in the control

valve and program the user sec-
tion of the control. Refer to control
valve programming section in this
manual.

Sanitization can also achieved by the application of chlorine in the regeneration cycle of the conditioner. A liquid solution
of 5.25% sodium hypochlorite (commonly referred to as household bleach) is recommended as a suitable disinfectant.
Use only unscented products. For every cubic foot of resin in the softener, pour approximately two (2) tablespoons of so-
dium hypochlorite into the brine well tube. The brine tank refill step of regeneration should add the correct amount of water
to the brine tank. If not, the water can be added manually now. Press and hold the

to begin a manual regeneration.

Allow softener to complete the Brine/Rinse cycle, then let the manual regeneration continue until the brine tank is refilled
again with the correct amount of water.

NOTE: ALL STATE AND LOCAL GOVERNMENT CODES GOVERNING INSTALLATION OF THESE DEVICES MUST BE OBSERVED.

18. Put 40 kgs of crystal water softener

salt in the brine tank. The unit will
automatically fill the water to the
correct level when it regenerates.

Optional Sanitization Procedure: We recommend that all new water conditioners be disinfected as

part of the startup.

Water Softener Sanitization

Press and Hold
to manually regenerate

Sanitization Solution

1a. Pour entire packet of Sani-System

Liquid Concentrate – Part # 50032
(24 packets) into the brine well. If
no brine well is present, pour entire
packet into bottom of brine tank
when salt is nearly empty.

1b. Manually regenerate the softener

according to the manufacturer’s
specifications.

1a

1b