18

5. Press . Use this display

to view the Volume
Used since the last
regeneration cycle. This
option setting is identified
by “VU” in the upper
left hand corner of the
screen.

6. Press . Use this display

to view the Reserve
Capacity. This option
setting is identified by
“RC” in the upper left
hand corner of the
screen.

7. Press . Use this display

to view the Software
Version. This option setting
is identified by “SV” in the
upper left hand corner of
the screen.

8. Press to end Diagnostic Programming Mode.

Diagnostic Programming Mode

Diagnostic Programming Mode Steps

1. Press the and buttons for five seconds while in

service.

2. Use this display to view

the current Flow Rate.
This option setting is
identified by “FR” in the
upper left hand corner
of the screen.

3. Press . Use this display

to view the Peak Flow
Rate since the last
regeneration cycle. This
option setting is identified
by “PF” in the upper
left hand corner of the
screen.

4. Press . Use this display

to view the Hours in
Service since the last
regeneration cycle. This
option setting is identified
by “HR” in the upper
left hand corner of the
screen.

Diagnostic Programming Mode Options

Abbreviation

Parameter

Description

FR

Flow Rate

Displays the current outlet flow rate

PF

Peak Flow Rate

Displays the highest flow rate measured since the last regeneration

HR

Hours in Service

Displays the total hours that the unit has been in service

VU

Volume Used

Displays the total volume of water treated by the unit

RC

Reserve Capacity

Displays the system’s reserve capacity calculated from the system
capacity, feed water hardness, and safety factor

SV

Software Version

Displays the software version installed on the controller

NOTES:
Some items may not be shown depending on timer configuration.
The timer will exit Diagnostic Mode after 60 seconds if no buttons are pressed.