Model S3TR Overall Dimensions
S3TR Typical Performance
167 Stock Street, Nesquehoning, PA 18240 Phone: 570-645-3779 Fax: 570-645-4061
Website
Curves are based on pumping water at 60°F. For performance curves other than shown above, consult factory.
8 1/2"
(21 cm)
(40 cm)
3" NPT (female)
11 3/4"
8 3/4"
(30 cm)
(22 cm)
15-3/4"
0
80
70
60
50
40
30
20
10
10
20
U.S.G.P.M.
Liters/Minute
Feet
Meters
300
A
B
C
D
CAPACITY
TOTAL HEAD
15
5
HYDRAULIC INPUT:
(A) 3 GPM @ 500-700 PSI
(B) 5 GPM @ 1000-1550PSI
(C) 5.2- 6.9 GPM @ 1600-2100PSI*
(D) 6.3 - 8 GPM @ 2500 PSI**
*Typical perf. with HT13 power unit
**Maximum performance