16

Safety instructions

use of the device that does not comply with the
instructions could present risks to people, nearby
installations and the environment.
• This device must be protected against electromagne-

tic interference, ultraviolet rays and, when installed

outdoors, the effects of climatic conditions.

• When the flowmeter is disassembled from the pipe,

take all the precautions associated with the process.

atex

Said appliance must be installed in accordance with
the provisions of standard EN 60079-14: electrical
appliance for potentially explosive atmospheres.
Part 14: electrical installations in dangerous sites (other
than mines).

English

17

7. DEScripTion
construction

The flowmeter SE30 Ex is an electronic module which must
be associated to a measuring element, either a fitting S030
(brass, stainless steel or PVDF) or a fitting S070.

atex

Depending on its place of use the SE30 Ex flowmeter
must be connected according to the safety instructions
of the chap. 6.

Electrical connection is made via a male fixed connector
EN 175301-803.

measuring principle

The sensor detects the rotation of the paddle-wheel and
modulates the current of the supply line as per the Namur
standard (0.5 mA or 2.5 mA). The modulation frequency f is
proportional to the flow rate Q using the formula f = KxQ.
f = frequency in Hz
K= factor K specific to each fitting, in pulse/l
Q = flow rate in l/s
In order to exploit this signal, connect a Namur type intrinsic
safety barrier to the SE30 Ex. It detects the modulation and
converts it to a frequency on its open collector output.

English

17

18

Description of the name plate

SE30EX-NAMUR
II 1 G/D Ex ia IIC T6
Ex iaD 20 IP6X T80°C
Tamb : 0°C - +60°C
LCIE 04 ATEX 6070 X
S/N:1000
00552901

W46LN

F-67220 TRIEMBAC

H

1

3

5

7

11

9

6

10

4

12

0102

2

8

1.

Protection rating

2.

Type of flowmeter

3.

Type of supply/output

4.

ATEX classification

5.

Maximum surface temperature

6.

Ambient operating temperature

7.

Certification body and ATEX number

8.

CE logo and code of notified body that inspected the site

9.

Manufacturing code and manufacturing year code

10.

Order code

11.

Serial number

12.

Ex logo

English

19

Available versions of the
electronic flowmeter SE30 Ex

All the versions of the SE30 Ex flowmeter:
• are energized through an intrinsic safety barrier ;
• have a Namur output.

version of the
se30 ex electronic
flowmeter

electrical connection order code

Namur II 1 G/D

Male fixed connector
EN 175301-803

552901

NamurI M 1

553455

English