Installation
7.5
rotating the control head for
process valves belonging to series 20xx
If the connecting cables or hoses cannot be fitted properly following installation of the process valve, the control
head can be rotated contrary to the actuator.
Fastening screw (2x)
Pneumatic connection
Control head
Actuator
Figure 16:
Rotating the control head, series 20xx
Procedure
→
Loosen the pneumatic connection between the control head and the actuator.
→
Loosen the fastening screws (hexagon socket wrench size 2.5).
→
Rotate the control head into the required position.
noTe!
too high torque when screwing in the fastening screw does not ensure degree of protection ip65 /
ip67.
▶ The fastening screw may be tightened to a maximum torque of 0.5 Nm only.
→
Tighten the fastening screws hand-tight only (maximum torque: 0.5 Nm).
→
Re-attach the pneumatic connections between the control head and the actuator. If required, use longer
hoses.
english
Type 8691
- Type 0125 (15 pages)
- Type 0121 (4 pages)
- Type 0330 (2 pages)
- Type 0331 (4 pages)
- Type 6012 (4 pages)
- Type 0127 (18 pages)
- Type 0131 (5 pages)
- Type 0141 (5 pages)
- Type 0142 (12 pages)
- Type 0145 (3 pages)
- Type 0174 (5 pages)
- Type 0212 (2 pages)
- Type 0211 (5 pages)
- Type 0212-B (18 pages)
- Type 0250 (64 pages)
- Type 0253 (2 pages)
- Type 0255 (15 pages)
- Type 0355 (2 pages)
- Type 0255 (2 pages)
- Type 8006 (34 pages)
- Type 8640 (2 pages)
- Type 8640 (55 pages)
- Type 8640 (119 pages)
- Type 0256 (15 pages)
- Type 0256 (2 pages)
- Type 0258 (72 pages)
- Type 0262 (5 pages)
- Type 0273 (6 pages)
- Type 0280 (5 pages)
- Type 0280 (2 pages)
- Type 0280 (12 pages)
- Type 0281 (2 pages)
- Type 0282 (2 pages)
- Type 0283 (2 pages)
- Type 0286 (4 pages)
- Type 0287 (15 pages)
- Type 0290 (2 pages)
- Type 0290 (14 pages)
- Type 0293 (18 pages)
- Type 0300 (6 pages)
- Type 0301 (6 pages)
- Type 0311 (2 pages)
- Type 0312 (6 pages)
- Type 6519 (3 pages)
- Type 6519 (4 pages)