Maintenance,cleaning

Warning!

for control function i – danger if pilot pressure fails!
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.

▶ To ensure a controlled restart, first pressurize the product with

pilot pressure, then switch on the medium.

10.2 maintenance work

10.2.1 actuator

The actuator of the diaphragm valve is maintenance-free provided it
is used according to these operating instructions.

10.2.2 Wearing parts of the diaphragm

valve

Parts which are subject to natural wear:
• Seals
• Diaphragm

If leaks occur, replace the particular wearing part with an appro-
priate spare part.
(see chapter entitled “13 Replacement parts”).

A bulging PTFE diaphragm may reduce the flow.

The replacing of the wearing parts is described in chapter
“11 Repairs”.

10.2.3 inspection intervals

Check diaphragm for wear after maximum 10

5

switching cycles.

Muddy and abrasive media require correspondingly shorter
inspection intervals!

10.2.4 service life of the diaphragm

The service life of the diaphragm depends on the following factors:
• Diaphragm material
• Medium
• Medium pressure
• Medium temperature
• Actuator size
• Pilot pressure for CFB and CFI.