13
Troubleshooting
13.1
Jerky running
13.2
Drive unit is running, conveyor belt is not
13.3
Motor overheating on drive unit
Cause
Corrective action
Damaged or badly fitted
slide rail
Inspect and replace as necessary.
Wrongly adjusted slip
clutch
Check and adjust slip clutch.
Worn transmission parts
Check/replace transmission belt, belt
drive sprocket.
Conveyor belt is too tight/
loose
Tension conveyor belt correctly.
Dirty conveyor
Clean conveyor belt/slide rail. Lubricate
with silicone based lubricant.
Cause
Corrective action
Wrongly adjusted slip
clutch
Check adjustment of slip clutch.
Friction discs in slip clutch
are worn or contaminated
Check and replace if necessary.
Damaged/badly fitted slide
rail
Check the free running of the conveyor
belt.
Transmission products are
not fitted
Check and fit.
Cause
Corrective action
Overloaded conveyor
Remove products from conveyor and test
run.
Check actual conveyor load against rec-
ommended loading.
Gearbox leaking oil
Check output shaft seal and area around
motor/gearbox interface.
Dirty conveyor
Clean the conveyor belt with warm water
(50°).