beautypg.com

Chapter 4 – menu system 45 diagnostics – Datamax-O'Neil M-Class Mark II Operator’s Manual User Manual

Page 51

background image

Chapter 4 – Menu System

45

Diagnostics

The Diagnostics menu contains testing functions and printhead reporting selections:

Hex Dump Mode

Options Testing

Print Test Rate (min)

Sensor Readings

Ribbon Sensor Limits

iPH Report

Icon Descriptions

The menu selections are defined as follows:

DISPLAYED ITEM

ITEM DESCRIPTION

HEX DUMP MODE

Determines how the printer handles the data received from a host, where:

ENABLE

The printer outputs the raw ASCII data it receives without interpretation; no
processing occurs.

DISABLE

Processes data normally. (Default Setting)

FILE CAPTURE

Saves the incoming data to Module H (USB thumbdrive) if present; otherwise, the
file is stored on Module G. The file name, in the form [dmx_xxx_yyy.dpl], where
the count is automatically incremented for every capture and a unique printer time

stamp (xxx), is assigned.

OPTIONS TESTING

Performs printer option diagnostics or monitors and outputs test results, where:

TEST PRESENT

SENSOR

Performs a functional test of the Present Sensor by indicating LABEL PRESENTED

(when a label blocks the sensor) and LABEL NOT PRESENTED (when no label blocks

the sensor). (Note that this test can also be used to check the sensor function of the
Peel & Present option.)

TEST CUTTER

Performs a functional test of the Cutter, where:

PERFORM

TEST

001 TIMES

Cycles the cutter blade a selected number of times (0 - 999), with PASS / FAIL

results given for each cycling attempt.

TEST GPIO

Performs a functional test of the GPIO port, where:

MONITOR

GPIO INPUT

Displays input signal logic values for Start of Print (SOP).

If unconnected, a zero or one may be displayed.

TEST GPIO

OUTPUT

Displays output signal logic values for End of Print (EP) and Service Required (SR).

To change an output signal state, cursor over the displayed state

to select and then toggle it using the UP or Down Arrow Buttons.

PRINT

SIGNAL INFO

Prints a reference label containing GPIO signal names, pin assignments, programmed

settings, and current signal states.

TEST RFID

Performs a functional test of the RFID option, where:

TAG DATA

Reads the data encoded on the RFID chip.

DEVICE

VERSION

Displays the type and version of the encoding device.

TAG ID - HF

ONLY

Reads and displays the High Frequency Tag ID number.

PRINT TEST RATE
(MIN)

Sets a label-to-label delay interval (0 - 120 minutes) when Test label batch printing,
where:

000

Is the Default Setting.