Chapter 3 - Printer Operation

20

3.5.3 Standard Calibration

The Standard Calibration can be performed using the DMXConfig Utility (see Section 3.4) and

using the front panel buttons (see Appendix C). On display-equipped printers the Standard
Calibration routine can also be initiated via the printer’s menu, see Section 4.5. Once you have

installed the DMXConfig utility and the printer is properly loaded with media:


1. Connect the host to the printer with a

serial or parallel cable.


2. Turn on the printer.

3. Launch the DMXConfig utility.

4. Query the printer by using the ‘Query

Printer’ toolbar button (top-left). This will
connect to the printer and get the current

printer settings.



5. Select the “Sensor Calibration” Tab and

then click the “Media Calibration Wizard”
button. When prompted click “OK” to start

the calibration wizard.





6. The Calibration Wizard will now prompt

you to ‘Load Stock’. Be sure the media is
properly loaded in the printer. Close the

printhead and click “OK”.