beautypg.com

Chapter 4 – menu system 42 – Datamax-O'Neil M-Class Mark II Operator’s Manual User Manual

Page 48

background image

Chapter 4 – Menu System

42

WLAN

Controls the communications settings for the network interface, where:

MODE

Selects between wired and wireless operation, where:

ENABLED

Enables the wireless interface. (This is the Default Setting.)

DISABLED

Enables the wired interface.

BSS

ADDRESS

Specifies the radio module’s static IP address; up to four octets separated by a

period. If Enable DHCP is checked, this parameter is ignored. Default is 0.0.0.0.

SIGNAL

READINGS

Provides a graphical representation of Signal Strength (in dBm), Noise Level (in

dBm), and Quality.

IP ADDRESS

Specifies the static IP Address of the interface in the standard octet format.

SUBNET MASK

Specifies the static Subnet assigned to the interface, for example:

255.255.255.000.

GATEWAY

Specifies the Gateway Address the interface will use, for example:

010.001.001.001.

SNMP TRAP

DESTINATION

Specifies the network IP Address where SNMP traps will be sent when SNMP service

is installed on your receiver. If zeroed, no traps are sent.

IP DISCOVERY

Sets the address discovery method, where:

ENABLED

The card broadcasts over the network to receive addresses from the responsible

server at startup. Manual modifications to IP Address, Subnet Mask, or Gateway

Address are not allowed; and, if no server is found, the specified static value will be
used. (Default Setting)

A server assigned IP address takes precedence over any static IP

address stored in the interface.

DISABLED

The stored static IP, Subnet Mask, and / or Gateway Address will be used.

SNMP Sets

SNMP

ENABLED (Default

Setting)

DISABLED

ADVANCED

Advanced settings for the NIC Card.

TELNET Enable/Disable

Telnet

protocol

FTP

Enable/Disable FTP protocol

MTU

Sets the Maximum Transmission Unit packet size, where:
Packet size, in bytes. (512-65515); Default is 1500

GRATUITOUS

ARP

Sets time interval for ARP transmission packets, where:

(0-2048 minutes); Default is 0

TCP
KEEPALIVE

Allows monitoring of an open connection to detect any disconnects not properly
closed, including reset access points and unplugged printers, where:

ENABLED

Keeps monitoring active.

DISABLED

Closes such a disconnection after 2.5 minutes. (Default Setting)

PORT

NUMBER

Selects the Port to use for all network communications; Default is 9100

DUPLEX

CAPABILTY

Specifies the transmission and speed of the wired Ethernet connection:

Auto-Negotiate (default);

100 BaseT Full Duplex;

100 BaseT Half Duplex;

10 BaseT Full Duplex; or,

10 BaseT Half Duplex

ADVERTISE

CAPABILITY

Selects the method in which the Duplex Capability setting is advertised, where:

Automatic (advertises the DUPLEX CAPABILITY setting); or,

All Capabilities (advertises all capabilities)

NETWORK

REPORT

Prints or displays a report which lists the printer’s network settings.

SET FACTORY

DEFAULTS

Resets NIC Adapter parameters to the factory defaults values.