Chapter 4 – Menu System

32

HF SETTINGS *

Sets HF tag parameters, as follows:

TAG TYPE

Sets the tag type:
ISO 15693 (Is the default setting.)

TI

PHILIPS

ST LRI512

ST LRI64

AFI VALUE

Application Family Identifier value (00 - FF), where 00 is the default value.

AFI LOCK

Application Family Identifier lock (ENABLED / DISABLED), where DISABLED is the

default setting.

DSFID VALUE

Data Storage Format Identifier (00 - FF), where 00 is the default value.

DSFID LOCK

Data Storage Format Identifier lock (ENABLED / DISABLED), where DISABLED is

the default setting.

EAS VALUE

Electronic Article Surveillance value (00 - FF), where 00 is the default value.

AUDIO
INDICATOR

Controls the buzzer (ENABLED / DISABLED), where DISABLED is the default
setting.

ERASE ON

FAULT

Erases the tag when errors are detected (ENABLED / DISABLED), where DISABLED

is the default setting.

UHF SETTINGS *

Sets UHF tag parameters, as follows:

TAG TYPE

Sets the tag type:

EPC 0

EPC 0+ MATRICS

EPC 0+ IMPINJ

EPC 1
UCODE EPC 1.19

EM 4022/1222

GEN 2 (Is the default setting.)

TAG DATA

SIZE

Sets the tag data size:

96-BIT (Is the default setting.)

64-BIT

POWER

ADJUST

Adjusts the applied power.

KILL CODE

Code used to permanently deactivate the device:

B3 B2 B1 B0

00 00 00 00 (Is the default setting.)

ACCESS
CODE

Code used to protect the memory contents:
B3 B2 B1 B0

00 00 00 00 (Is the default setting.)

GEN 2 LOCK

ACTION

Sets the lock level (NONE, PERMALOCK, PWD-READ/WRITE, BOTH), where NONE is

the default setting.

LOCK AFTER
WRITE *

Locks the tag after programming.

ENABLED

The tag will be locked.

DISABLED

No locking occurs (default setting).

RETRY

ATTEMPTS *

Sets the number of retry attempts, where:

(0 - 9)
3

Zero to nine are the number of retries; and,
Is the default setting.

PERFORM

CALIBRATION *

Allows the printer to establish the tag to transducer distance setting and nominal

RFID power requirements.

YES

Initiates the process. The CALIBRATING RFID message will appear as the printer

feeds media to begin scanning for the RFID tag location. Once the location is

established, power calibration begins. Upon completion, the media will be retracted

to the TOF position; the calibrated position and power results (along with a brief

SUCCESS or FAILURE message) will be displayed; and, the printer’s database will

be updated with the new calibration parameters.

NO

Terminates the process.