beautypg.com

Chapter 4 – menu system 26 – Datamax-O'Neil M-Class Mark II Operator’s Manual User Manual

Page 32

background image

Chapter 4 – Menu System

26

DISPLAYED ITEM

ITEM DESCRIPTION

MEDIA TYPE

Selects the method used to print labels and should be set according to the type

of media being used, where:

DIRECT THERMAL

Sets use for media that is heat reactive to produce an image.

THERMAL

TRANSFER

Sets use for media that requires a ribbon to produce an image.

SENSOR TYPE

Selects the top-of-form (TOF) sensing method used to determine the leading

edge of the label, where:

GAP

TOF will be recognized by sensing the gaps or notches in the media. (Default

Setting)

CONTINUOUS

No TOF sensing will be used; instead, LABEL LENGTH (in Media Settings) is used.

REFLECTIVE

TOF will be recognized by sensing the reflective (black) marks on the underside
of the media.

LABEL LENGTH

Determines the length of the label (0 - 99.99 inches) when the SENSOR TYPE is

set to CONTINUOUS, where:

04.00

Is the default setting.

MAXIMUM LABEL

LENGTH

Sets the distance (0 - 99.99 inches) that the printer will feed media to find TOF

(when the Sensor Type is set to GAP or REFLECTIVE) before a TOF Fault is

declared, where:

16.00

Is the default setting.

Maximum Label Length should typically be 2.5 to 3 times the physical length of the label.

PAPER EMPTY

DISTANCE

Sets the distance (0 - 99.99 inches) the printer will attempt to feed before an

Out Of Stock Fault is declared, where:

00.25

Is the default setting.

When using clear or translucent media, this setting should be longer than the actual label size.

LABEL WIDTH

Sets the maximum printable width. Objects extending beyond this setting will

NOT print, where:

x.xx

Default setting is dependant on printer model.

RIBBON LOW

OPTIONS

Defines the printer response when THERMAL TRANSFER mode is selected and the

ribbon supply begins to diminish.

RIBBON LOW
DIAMETER

Sets the ribbon supply threshold diameter (1.00 - 2.00 inches) that will trigger a
Low Ribbon Warning prompt, where:

1.38

Is the default setting.

PAUSE ON RIBBON

LOW

Allows the printer to enter a paused condition when Ribbon Low Diameter is met,

where:

ENABLE

Pauses when a Ribbon Low Diameter condition is detected; the PAUSE Key must

be pressed to proceed with the print job.

DISABLE

No action is required by the operator; printing can continue until a Ribbon Fault

is declared. (Default Setting)