beautypg.com

Chapter 4 – menu system 43 – Datamax-O'Neil M-Class Mark II Operator’s Manual User Manual

Page 49

background image

Chapter 4 – Menu System

43

HOST SETTINGS

Controls the communications with a host device, where:

The "ignore host" settings for ESC SEQUENCES, HEAT, SPEED,
TOF SENSING, SYMBOL SET, CNTRL-CODES, STX-V SW

SETTINGS, and MAX LENGTH will be unaffected when PL-Z Mode

is selected (see Input Mode for details).

HOST TIMEOUT

Sets the number of seconds (1 - 60) that an established communications port must

be idle before data can be received through an alternate port, where:

If the time-out period is exceeded before all data is received, the

data will be ignored.

10

Is the Default Setting.

CONTROL

CODES

Allows changes to the prefix of the software commands interpreted by the printer,

where:

STANDARD

CODES

Use these characters: Hex 01 = SOH command; Hex 02 = STX command; count-by

= ^; Hex 1B = ESC; Hex 0x0D = Carriage Return. (Default Setting)

ALTERNATE
CODES

Use these characters: Hex 5E = SOH command; Hex 7E = STX command; count-by
= @; Hex 1B = ESC; Hex 0x0D = Carriage Return.

ALTERNATE
CODES 2

Use these characters: Hex 5E = SOH command; Hex 7E = STX command; count-by

= @; Hex 1B = ESC; Hex 0x7C = Carriage Return.

CUSTOM

CODES

Each DPL command (SOH, STX, CR, and count-by) may be selected by entering the

desired Hex code.

FEEDBACK
CHARACTERS

Allows the printer to return a Hex 1E (RS) after each label successfully prints, and a
Hex 1F (US) after each label batch successfully prints, where:

ENABLED

Sends feedback characters to the host.

DISABLED

Does not send feedback characters to the host. (Default Setting)

ESC

SEQUENCES

Allows data containing invalid ESC control code sequences to be processed, where:

ENABLED

Processes commands normally. (Default Setting)

DISABLED

Ignores ESC sequences are during processing (since some systems send a “banner”

to the printer). Bitmapped font downloads are disabled in this mode.

HEAT

COMMAND

Determines the way the DPL Heat command is handled, where:

ENABLED

Processes commands normally. (Default Setting)

DISABLED

Ignores DPL Heat commands; instead, the heat value is controlled via the menu

setting.

SPEED
COMMANDS

Determines the way DPL Print, Feed, Slew, and Reverse commands are handled,
where:

ENABLED

Processes commands normally. (Default Setting)

DISABLED

Ignores DPL speed commands; instead, the speeds are controlled via the menu
setting.

TOF SENSING

COMMANDS

Determines the way in which DPL Gap, Continuous, and Reflective commands are

handled, where:

ENABLED

Processes commands normally. (Default Setting)

DISABLED

Ignores DPL TOF commands; instead, TOF is controlled via the menu setting.

SYMBOL SET

COMMAND

Determines the way in which DPL Single and Double Symbol Set commands are

handled, where:

ENABLED

Processes commands normally. (Default Setting)

DISABLED

Ignores DPL Symbol Set commands; instead, the Symbol Set selection is controlled

via the menu setting.

CNTRL-CODES

(DATA)

Determines the way in which DPL SOH, STX, CR, ESC, and ^ codes are handled,

where:

ENABLED

Processes commands normally. (Default Setting)

DISABLED

Ignores DPL Control Codes; instead, the control code functions are established via

the menu setting.