beautypg.com

Chapter 4 – menu system 44 – Datamax-O'Neil M-Class Mark II Operator’s Manual User Manual

Page 50

background image

Chapter 4 – Menu System

44

STX-V SW

SETTINGS

Determines the way in which the DPL V command is handled, where:

ENABLED

Processes commands normally. (Default Setting)

DISABLED

Ignores the option-enable command; instead, the option selections are controlled

via menu settings.

MAX LENGTH

COMMAND

Determines the way in which the DPL M command is handled, where:

ENABLED

Processes commands normally. (Default Setting)

DISABLED

Ignores the maximum label length command; instead, Maximum Label Length is

controlled via the menu setting.

OPTION

FEEDBACK

Allows feedback characters from an optional device to be returned to the host
device, in the format of: [CR]

Where:

A -

Is the device type: R = RFID; and, S = Linear Scanner

B -

Is the resulting status: C = entire label complete; F = faulted (failed)
label; and, U = unknown

C -

Is the number of expected reads, given in two characters.

D -

Is the number of good reads, given in two characters.

E -

Is the internal Job and Sub Job Identifier, given in four characters each.

F -

Is the data that was read, delimited with semicolons (;) on multiple reads.

DISABLED

No data is reported. (Default Setting)

SCANNER

Linear Scanner information is reported.

RFID HEX

RFID information is reported in hexadecimal format.

RFID ASCII

RFID information is reported in an ASCII format.

PROCESS SOH

(DATA)

Determines the way the printer responds to an Immediate Command (e.g., Get

Status, Module Storage, etc.), where:

ENABLED Operations

are

interrupted

upon receipt to process the command.

DISABLED