7.6.6.1 - TO CHECK THE ENCODER
When the spindle is rotated:
- the angular position “POS” should vary from 0 to 128;
- the wording “UP” should appear when rotated clockwise and “DOWN” when rotated in the opposite
direction.


Encoder check

Check for correct
operation of the dis-
tance gauge;
the number
increases when the
gauge is pulled out.

Check for correct oper-
ation of the diameter
gauge; the number
increases when the
gauge is rotated out-
wards

Check of the width sonar:
the number decreases
when a surface is
approached to the sonar

Check of the eccentricity sonar (option):
the number decreases when a surface is
approached to the sonar

In the event of failure or faulty operation of the wheel balancing machine, notify the Technical Service
of all the parameters displayed.